NAME | METHOD | REFERENCE RANGE | UNITS |
![]() |
Cardiolipin IgG Autoantibodies | EIA | view ref range | GPL U/mL |
![]() |
Cardiolipin IgM Autoantibodies | EIA | view ref range | MPL U/mL |
![]() |
Cardiolipin IgA Autoantibodies | EIA | < 13 | APL U/mL |
![]() |
Thrombin Time | CLOT DET | 11.4 - 15.9 | seconds |
![]() |
Lupus Anticoagulant Hexagonal Phase | CLOT DET | < 8.0 | |
![]() |
Prothrombin Time | CLOT DET | 10.4 - 13.5 | seconds |
![]() |
International Normalized Ratio | CALC | view ref range | |
![]() |
Activated Partial Thromboplastin Time | CLOT DET | 27 - 38 | seconds |
![]() |
LAC Screen Result | CLOT DET | < 1.21 |
![]() |
TYPE | VOLUME | TEMPERATURE | INSTRUCTIONS |
PRIMARY | ||||
1 | Plasma Citrated | 3 (1.5) mL | Frozen - 14 Day(s) | See COLLECTION INSTRUCTIONS for platelet-poor plasma. |
2 | Serum | 1 (0.5) mL | Refrigerated - 48 Hour(s), Frozen - 2 Month(s) |
Antiphospholipid antibodies are found in wide range of conditions, either transiently such as in some infectious diseases, or more persistently in autoimmune diseases such as SLE. Antiphospholipid antibodies are associated with fetal loss, endocarditis, stroke, heart attack and autoimmune hemolytic anemia. |
Instructions for platelet-poor plasma:
1. Draw a plain red top tube to remove tissue fluid contamination. Discard this tube. 2. Draw blood into a buffered citrate collection tube (light blue top) filled to the proper level. Do not overfill. 3. The blood-to-anticoagulant ratio should be 9:1; inadequate filling of the collection device will decrease this ratio and may lead to inaccurate results. 4. Adjust the final citrate concentration in the blood of patients who have hematocrit values above 0.55 (55%). For hematocrits below 20%, there are no current data to support a recommendation for adjusting the citrate concentration. 5. The needle gauge could be between 19-22. For pediatric patients a 21-23 gauge needle may be used. 6. Invert gently 6 times to mix. Process immediately. 7. Centrifuge for 15 min at 2500 x g. 8. Remove plasma using a plastic pipette and transfer to a new tube. 9. Repeat centrifugation at 2500 x g for 15 min to assure complete platelet removal. 10. Dispense the plasma into 2 or more plastic tubes using a plastic transfer pipette. Label tubes appropriately. 11. Freeze immediately. Stable for 2 months at -20 C and 6 months at -70 C. 12. Specimen must remain frozen at all times. Ship to Specialty within 24 hours on dry ice. 13. Specimen should not be submitted if it is hemolyzed, microclots are present, the tube is less than 90% filled or a specimen with hematocrit >55% is collected without anticoagulant adjustment. |